SDA04 is a complete, stand-alone fingerprint recognition system that captures and stores fingerprint data and identifies or verifies registered users. Designed to function entirely without an external PC, the SDA04 can be integrated into access control units, door locks and other products. It can communicate with external devices and is interoperable with data input from SecuGen USB fingerprint readers for a wide variety of implementations.
Technical Specifications | Developer Kit | Datasheet | User Guide
SDA04 uses next-generation fingerprint technology including SecuGen’s ruggedized, high image quality fingerprint optic module and high speed NIST MINEX Compliant fingerprint matching algorithms for fast 1:1 and 1:N search capabilities, and is FBI Certified as meeting FBI Image Quality Specs (IQS) and compliant with FIPS 201 standard for PIV Single Finger Readers.

|
|
| Technical Specifications |
| CPU |
533 MHz ARM |
| Flash |
128 MB |
| User Capacity |
10,000 |
| 1:1 Verification Time |
0.1 sec |
| 1:N Identification Time |
0.2 sec |
| Enrollment Time |
0.9 - 1.3 sec (capture + extraction) |
| Fingerprint Template |
Proprietary (400 bytes), ANSI-INCITS 378-2004 (variable size) |
| Supply Voltage |
3.3V DC |
| Operating Current Consumption |
110 mA |
| Max Current Consumption |
550 mA |
| Communication Speed |
921600 BPS (max) |
| Host Communication |
Serial (RS 232, TTL)
|
| External Interface |
Weigand output,
GPIO input (2),
GPIO output (2 relay, 2 sw) |
| Optic Module |
SDOPP04 |
| Image Resolution |
500 dpi |
| Image Size |
258 x 336 pixels |
| Image Gray Scale |
256 shades (8-bit gray level) |
| Non-Linear Distortion |
~0% |
| Effective Sensing Area |
12.9 x 16.8 mm |
| Platen Hardness |
750 Hk (~6.8 Mohs) |
| Light Source |
Red LED |
| Typical Lifetime |
60,000 hours |
| Ambient Light Tolerance |
5,000 Lux (50,000 Lux with Smart Capture) |
| Dimensions |
21 x 32 x 62 mm (optic module),
59 x 43 x 8 mm (PC board) |
| Operating / Storage Temp. |
- 20° to 65°C / - 40° to 85°C |
| Humidity |
90% RH or less |
| ESD Tolerance |
13 kV |
| FAR and FRR |
Read our FAQs |
| Other features |
Auto-On |
| Compliance |
RoHS, NIST FIPS 201 & SP 800-76 |
| Certification |
GSA FIPS 201 APL, FBI Image Quality Specification (IQS) |
| SDA04 Developer Kit (sold separately) |
The Developer Kit includes all the hardware, software, support and documentation needed to accelerate the design and integration of SDA04 into stand-alone or networked devices. The Developer Kit also includes APIs and data conversion modules to help expand the capabilities of your fingerprint biometric system with the following functions:
- Register, update and delete user profiles
- Verify or identify user
- Manage user database
- Control system settings (brightness, exposure, gain, security levels, quality threshold, etc.)
- Test all functions
- Interface with PC and SecuGen USB fingerprint readers
|
| Components |
SDA04 (1 unit), DB9 interface board for development, C9 cable, RS232 cable, 3.3V AC-DC power supply, software, documentation |
| Maintenance |
First year included
- Tech support
- Free software upgrades
- Access to SGDN (SecuGen Developer Network) |
Read Press Release about: FBI certification announcement